Venturi mask delivers how much oxygen




















Disadvantages: The partial re-breather bag has no one-way valves, so the expired air mixes with the inhaled air. The mask may be hot and confining for the patient and will interfere with eating and talking. Face tents are used to provide a controlled concentration of oxygen and increase moisture for patients who have facial burn or a broken nose, or who are are claustrophobic. Delivers a more precise level of oxygen by controlling the specific amounts of oxygen delivered.

The port on the corrugated tubing base of the mask sets the oxygen concentration. Delivers humidified oxygen for patient comfort. It does not dry mucous membranes. Disadvantages: The mask may be hot and confining for some patients, and it interferes with talking and eating. Need a properly fitting mask. Nurses may be asked to set up a high-flow system.

In other instances, respiratory therapists may be responsible for regulating and monitoring the high-flow systems. The use of oxygen delivery systems is only one component to increasing oxygen to the alveolar capillary bed to allow for optimal oxygenation to the tissues. Additional methods to increase oxygen saturation levels in the body include Perry et al. Skip to content Chapter 5. Oxygen Therapy.

Explain the difference between low- and high-flow oxygen systems. The reservoir bag on a non re-breather mask and a partial re-breather mask must always be kept partially inflated. Previous: 5. Next: 5. Share This Book Share on Twitter. Types of Oxygen Equipment. Additional Information. Nasal cannula consists of a small bore tube connected to two short prongs that are inserted into the nares to supply oxygen directly from a flow meter or through humidified air to the patient.

It is used for short- or long-term therapy i. Applying a nasal cannula Nasal cannula. A mask fits over the mouth and nose of the patient and consists of exhalation ports holes on the side of the mask through which the patient exhales CO 2 carbon dioxide.

These holes should always remain open. The mask is held in place by an elastic around the back of the head, and it has a metal piece to shape over the nose to allow for a better mask fit for the patient.

Humidified air may be attached if concentrations are drying for the patient. Simple face mask. Consists of a simple mask and a small reservoir bag attached to the oxygen tubing connecting to the flow meter. With a re-breather mask, there is no re-breathing of exhaled air. It has a series of one-way valves between the mask and the bag and the covers on the exhalation ports. On inspiration, the patient only breathes in from the reservoir bag; on exhalation, gases are prevented from flowing into the reservoir bag and are directed out through the exhalation ports.

Non re-breather mask. The bag should always remain partially inflated. The flow rate should be high enough to keep the bag partially inflated. Partial re-breather mask. The mask covers the nose and mouth and does not create a seal around the nose. Disadvantages: It is difficult to achieve high levels of oxygenation with this mask. Oxygen therapy via a venturi system can be delivered from an oxygen cylinder or via a piped source.

For safety purposes, if using an oxygen cylinder, the nurse must ensure that a replacement cylinder is available when the volume indicator gauge shows approximately one quarter full. The nurse must also ensure that patients and visitors are made aware of the dangers of smoking when oxygen is being administered as it is highly inflammable. The use of paraffin or other flammable substances should not be used around the patient due to the fire risk NPSA Clinical Alert.

Elsevier Clinical Skills covers the principles of this procedure. You must follow local policies and procedures regarding technique, equipment used and documentation. Figure 1. Oxygen cylinder. Mosby Elsevier, Edinburgh.

Figure 2. Figure 3. Mask with venturi system. Learning Objective. Rationale — Oxygen is prescribed when the patient has a need and therefore the patient must be monitored to ensure that it is achieving the goal.

All rights reserved. Venturi connector colour. Percentage oxygen.